How to size a room air conditioner
Start with ENERGY STAR's capacity for the room's area
Heavily shaded: − 10%, very sunny: + 10%
Each person above two: + 600 BTU
Kitchen: + 4,000 BTU
Example: a 12 × 16 ft bedroom that gets a lot of sun, used by three people.
- Area: 12 × 16 = 192 sq ft, in the 150 up to 250 sq ft band: 6,000 BTU
- Very sunny: + 10% = 6,600 BTU
- One person above two: + 600 = 7,200 BTU per hour
- That’s 7,200 × 0.293 = 2.1 kW, or 0.6 tons
ENERGY STAR’s chart
| Area to be cooled | Capacity |
|---|---|
| 100 up to 150 sq ft | 5,000 BTU/h |
| 150 up to 250 sq ft | 6,000 BTU/h |
| 250 up to 300 sq ft | 7,000 BTU/h |
| 300 up to 350 sq ft | 8,000 BTU/h |
| 350 up to 400 sq ft | 9,000 BTU/h |
| 400 up to 450 sq ft | 10,000 BTU/h |
| 450 up to 550 sq ft | 12,000 BTU/h |
| 550 up to 700 sq ft | 14,000 BTU/h |
| 700 up to 1,000 sq ft | 18,000 BTU/h |
| 1,000 up to 1,200 sq ft | 21,000 BTU/h |
| 1,200 up to 1,400 sq ft | 23,000 BTU/h |
| 1,400 up to 1,500 sq ft | 24,000 BTU/h |
| 1,500 up to 2,000 sq ft | 30,000 BTU/h |
| 2,000 up to 2,500 sq ft | 34,000 BTU/h |
The capacities assume an 8 ft ceiling. The calculator reads “100 up to 150” as 100 sq ft or more but less than 150, so a room right on a boundary takes the larger size. It applies the 10% for sun to the chart’s figure first, then adds people and the kitchen; ENERGY STAR doesn’t say in which order. Rooms under 100 sq ft get the chart’s smallest size, 5,000 BTU.
A rule of thumb, not a load calculation
The chart sizes a room unit from floor area, with only the sun, people and kitchen adjustments. For a whole house, ENERGY STAR asks contractors to calculate the heating and cooling loads with ACCA Manual J or equivalent, and to size central air, heat pumps and furnaces from that. To check your attic against ENERGY STAR’s insulation levels, use the insulation calculator.
What’s not covered
Heating and furnace sizing, and whole-house systems over 2,500 sq ft, are beyond ENERGY STAR’s room chart. Ask an HVAC contractor for a Manual J load calculation.