Rafter length on a 2/12 roof
Rafter line length = run × 1.014. On a simple gable the run is half the building's width.
| Run | Gable width | Rise | Rafter line length |
|---|---|---|---|
| 12 ft | 24 ft | 2 ft (2.00 ft) | 12 ft 2 in (12.17 ft) |
| 14 ft | 28 ft | 2 ft 4 in (2.33 ft) | 14 ft 2 in (14.19 ft) |
| 16 ft | 32 ft | 2 ft 8 in (2.67 ft) | 16 ft 3 in (16.22 ft) |
From the wall line to the center of the ridge. Overhangs, the ridge board and the seat cut change the length of board to buy.
Roof area at 2/12
Roof area = flat plan area (the roof seen from above) × 1.014. Roofing is measured in squares of 100 sq ft of roof surface.
| Plan area | Roof area | Squares |
|---|---|---|
| 1,000 sq ft | 1,014 sq ft | 10.14 |
| 1,500 sq ft | 1,521 sq ft | 15.21 |
| 2,000 sq ft | 2,028 sq ft | 20.28 |
| 2,500 sq ft | 2,534 sq ft | 25.34 |
Before waste. The roofing calculator adds waste and counts bundles, underlayment and nails.
Roofing allowed at 2/12
2/12 is in the shingle makers' low-slope range, 2:12 up to (not including) 4:12. Shingles are allowed, but each maker asks for more underlayment than on steeper roofs.
Asphalt shingles: what the makers say
- GAF: allowed. For slopes 2:12 to less than 4:12: “Completely cover the deck with two layers of GAF Roof Deck Protection.” At eaves and where ice dams can be expected, one layer of GAF Leak Barrier, which “should extend 24" (610 mm) beyond the inside wall line.” GAF’s 2025 Pro Field Guide also allows a single layer of StormGuard or WeatherWatch leak barrier instead of the double layer. (Timberline HDZ instructions; GAF Pro Field Guide)
- Owens Corning: allowed. For 2:12 to less than 4:12: “Option 1: Install 2 layers of Owens Corning®, RhinoRoof®, or Titanium® Synthetic Underlayment or equivalent underlayment meeting ASTM D8257,” each course “overlapped a minimum of 1/2 the width of the underlayment course below, plus 2 inches.” “Option 2: Install Owens Corning® Self-Adhered Ice & Water Barrier or equivalent with a standard overlap of 3 inches and metal drip edge.” (Duration instructions)
- CertainTeed: allowed. “All roof shingles applied to a low slope deck (2" to below 4" per foot) require the use of CertainTeed WinterGuard or VYCOR® Waterproofing Shingle Underlayment, or its equivalent, applied over the entire deck surface.” Equivalents include ASTM D1970 waterproofing underlayments and, “in areas not prone to snow or ice, two layers of 36" (915 mm) wide felt shingle underlayment lapped 19" (485 mm),” or two half-lapped layers of DiamondDeck or RoofRunner. In the Pacific Northwest, CertainTeed requires waterproofing underlayment over the entire deck. (Landmark installation guide)
Steep-slope nailing applies only at 21/12 and above (GAF) or above 21/12 (Owens Corning, CertainTeed), far steeper than 2/12.
Low-slope roofing systems
- GAF Liberty SBS self-adhering roofing: for slopes “between 1/4:12 and 3:12”.
- Owens Corning DeckSeal self-adhered roofing: for slopes “between 1/4:12 and 2:12”.
What the model code allows
Minimum slopes in the International Residential Code (R905), as the calculator page uses them. Your local code and the product's instructions can be stricter.
| Roof covering | Minimum slope | At 2/12 |
|---|---|---|
| Membrane roofing (built-up, modified bitumen, single-ply) | 1/4 in 12 | Allowed |
| Standing-seam metal panels | 1/4 in 12 | Allowed |
| Lapped metal panels with lap sealant | 1/2 in 12 | Allowed |
| Asphalt shingles | 2/12 | Allowed |
| Clay or concrete tile | 2.5/12 | Too flat |
| Lapped metal panels without sealant | 3/12 | Too flat |
| Metal roof shingles | 3/12 | Too flat |
| Wood shingles and shakes | 3/12 | Too flat |
| Slate | 4/12 | Too flat |
Up to 4/12 the code also calls for two layers of underlayment under asphalt shingles (from 2/12) and clay or concrete tile (from 2.5/12).
Is a 2/12 roof walkable?
No source we use rates a pitch as safe to walk on. OSHA's fall protection rules sort roofs into two groups: a low-slope roof has "a slope less than or equal to 4 in 12," and a steep roof "a slope greater than 4 in 12." By that definition, 2/12 is a low-slope roof.